Passive House Technical Detail

Passive house technical detail of a certified building. For further information regarding our Passive Houses please contact us today info@moduland.eu

High Performance Passive Houses

A Passive House is a precisely engineered and detailed structure that is highly insulated, cold bridge free and requires 90% less energy for space heating or cooling. Building a Passive House does not cost extra in the long term as there is no need to install a complex heating system. Finances saved are invested into essential Passive House Elements, the cost of which is quickly recouped within a few years of building completion. A Passive House is fitted with a variety of non structural high performance essential elements, which include:

  • Triple gazed windows
  • Thermal Insulation barrier
  • Airtight membrane and tapes
  • Heat Recovery Ventilation Unit (HRV)

Thermal insulation

All opaque building components of the exterior envelope of the house must be very well-insulated. This means a heat transfer coefficient (U-value) of 0.15 W/(m²K) at the most, i.e. a maximum of 0.15 watts per degree of temperature difference and per square metre of exterior surface are lost.

Passive House windows

The window frames must be well insulated and fitted with low-e glazings filled with argon or krypton to prevent heat transfer. This is achieved by a U-value of 0.80 W/(m²K) or less, with g-values around 50% (g-value= total solar transmittance, proportion of the solar energy available for the room).

Ventilation heat recovery

Efficient heat recovery ventilation is key, allowing for a good indoor air quality and saving energy. In Passive House, at least 75% of the heat from the exhaust air is transferred to the fresh air again by means of a heat exchanger.

Airtightness of the building

Uncontrolled leakage through gaps must be smaller than 0.6 of the total house volume per hour during a pressure test at 50 Pascal (both pressurised and depressurised).

Absence of thermal bridges

All edges, corners, connections and penetrations must be planned and executed with great care, so that thermal bridges can be avoided. Thermal bridges which cannot be avoided must be minimised as far as possible.

Foundation & Slab System

Our foundation and slab is designed to thermally encase the foundation in high performance expanded polystyrene (EPS) insulation, which delivers the lowest U-Vaule currently available at 0.105W/m2K.

Wall System

Our wall system delivers a U-Value of 0.12W/m2K and is designed to perform to its optimum level when used in tandem with our Foundation & Slab system.

Roof System

Our roof system delivers a U-Value of 0.10W/m2K and is suitable for all roof designs (flat, pitch, barrel vault, etc), ensuring your desired building design remains unchanged.